SMA Solar Technology AG Decommissioning
Installation Guide SB13_21TL-IA-IEN121060 57
10 Decommissioning
10.1 Disassembling the Inverter
1. Open the inverter as described in section 7.2"Opening the Inverter" (page39).
2. Remove all cables from the inverter.
3. Close the inverter with the 4 screws.
4. Loosen the lower screw between the inverter and
the wall mounting bracket.
5. Lift the inverter off the wall mounting bracket.
☑ The inverter is disassembled.
CAUTION!
Risk of injury due to the heavy weight of the inverter.
• Note that the inverter weighs approx. 16 kg.