Opening and Closing SMA Solar Technology AG
42 SB13_21TL-IA-IEN121060 Installation Guide
7.3 Closing the Inverter
1. Establish the protective conductor (PE) connection to the lid.
2. Secure the enclosure lid of the inverter by evenly
tightening the 4 lid screws.
3. Attach the AC plug.
4. Check the DC connectors for correct polarity and connect them.
To unlock the DC connectors see section 7.2"Opening the Inverter" (page39).
5. Close all the DC inputs that are not needed as described in section 5.4.4"Connecting the PV
Array (DC)" (page33) in order to seal the inverter.