SMA Solar Technology AG Failure Search
Installation Guide SB13_21TL-IA-IEN121060 49
Imax / overcurrent Overcurrent on the AC side. This message is displayed if the current on
the AC grid is larger than specified.
Corrective measures
Check the plant design and grid conditions.
K1-Close
K1-Open
K2-Open
Error during relay test.
Corrective measures
Contact the SMA Serviceline if this fault occurs frequently or
repeatedly.
MSD-dI
MSD-Fac
MSD-Vac
MSD-Timeout
MSD-Zac
Internal measurement comparison fault or hardware defect.
Corrective measures
If this fault continues to occur, contact the SMA Serviceline.
Offset The "Offset" operating state is a normal operating state that occurs prior
to grid monitoring. If "Offset" is displayed as an error, then there is a data
logging disturbance.
Corrective measures
If this fault continues to occur, contact the SMA Serviceline.
Riso The electrical insulation of the PV plant to ground is faulty. The resistance
between the DC plus and/or DC minus connection and ground is outside
the defined limit range.
Corrective measures
Check the plant insulation.
Check the plant for ground faults as described in section
9.3.1"Checking the PV Array for a Ground Fault" (page52).
ROM The inverter firmware is faulty.
Corrective measures
If this fault continues to occur, contact the SMA Serviceline.
Shutdown Temporary inverter disturbance.
Corrective measures
Contact the SMA Serviceline.