Displays and Messages Measuring Channels and Parameters
SB3000US-4000US-11-SE1607 SMA America 7-17
Measuring Channels and Parameters
The communication options support a number of measuring channels and messages
from the Sunny Boy inverters.
The following abbreviations are used:
BFR Betriebsführungsrechner (Sequential Control System)
SRR Stromregelungsrechner (Current Control System)
The BFR and SRR are redundant processor control systems for the utility protection
functions.
Measuring Channels
Vpv: PV input voltage
Vpv Setpoint: MPPT DC voltage target
Iac: Grid current
Vac: Grid voltage L1 - L2
Vac L1: Grid voltage L1 - N
Vac L2: Grid voltage L2 - N
Fac: Grid frequency
Pac: Power fed to grid
Vpv-PE: PV-voltage to earth (For troubleshooting PV ground faults)
Temperature: Temperature measured at IGBT module
Ipv: PV current
Max Temperature: Max temperature measured at IGBT
Max Vpv: Max PV input voltage
I-dif: Error current
Vfan: Fan voltage
E-Total: Total energy yield
h-Total: Total operation hours