Mounting Mounting Procedure
3-10 SMA America SB3000US-4000US-11-SE1607
Mounting the SMA DC-Disconnect (if applicable)
Figure 3-8 Mounting the SMA DC-Disconnect
Attach the SMA DC-Disconnect to the two lower holes of the wall-mounting bracket,
using two M6 x 10 screws and washers provided. The teeth of the washers should
face towards the wall in order to ensure proper grounding. Tighten the screws to a
torque of 44 in-lb (5 Nm).