9 Operation
SMA Solar Technology AG
Operating Manual STPx0-3SE-40-BE-en-10 73
Position Designation Description
D Status bar Displays the following information:
• Inverter serial number
• Inverter firmware version
• IP address of the inverter within the local network
and/or IP address of the inverter during WLAN
connection
• With WLAN connection: Signal strength of WLAN
connection
• User group logged in
• Date and device time of the inverter
E Current power and cur-
rent consumption
Temporal progression of the PV power and the power
consumption of the household over the selected time pe-
riod. Please note, the power consumption will only be dis-
played if an energy meter is installed in the PV system.
F Status display The various areas display information on the current status
of the system.
• Device status
Displays whether the inverter is currently in a fault-
free operating state or whether there is an Error or
Warning present.
• System overview
Shows the current power flows between the
components of the system.
• Yield
Displays the energy yield of the inverter.
• Nominal energy throughput of the battery
Indicates how much energy has been charged to the
battery and how much has been discharged from the
battery.
• Energy exchange at the grid-connection point
Indicates which power is currently fed in or obtained
at the grid-connection point.
9.4 Displaying and Downloading the Stored Data
When a smart device is connected to the product via LAN or Wi-Fi, you can view and download
the stored data.
Procedure:
1. Open the user interface (see Section9.1, page66).
2. Log into the user interface (see Section9.2, page69).