CN4
1
2
3
4
5
6
7
8
9
10
11
12
13
14
COM+
COM−
OUTJ+
OUTJ−
OUT0
OUT1
BUSY
ALARM
JOG+
JOG−
IN0
IN1
RESET
STOP
COM+
COM−
OUTJ+
OUTJ−
OUT0
OUT1
BUSY
ALARM
JOG+
JOG−
IN0
IN1
RESET
STOP
1
2
3
4
5
6
7
8
9
10
11
12
13
14
CN4
Wiring Diagram
How to Order
XB182
LE
LE P
1
C
DIN rail
Not mountable
D
Mountable
I/O cable length
Without cable
1
1.5 m
3
3 m
5
5 m
Parallel input/output type
N
NPN
P
PNP
Compatible motor
P
Step motor (Servo/24 VDC)
Electric actuator
Controller
With input signals to perform jog
operations (Stop points: 2 points)
Actuator part number
P
NPN PNP
Parallel I/O connector: CN4
When you connect a PLC to the CN4 parallel I/O connector, use the I/O cable (LEC-CK4-).
The wiring changes depending on the type of parallel I/O (NPN or PNP).
(Enter the portion from the actuator model “LE” to the “stroke”.)
Example: Enter “LEHZ10LK2-4” for the LEHZ10LK2-4AF-R11N1D.
The DIN rail is not included.
It must be ordered separately.
LECP1-XB182
Load
Load
Power supply 24 VDC
for I/O signal
Power supply 24 VDC
for I/O signal
Load
Load
Load
Load
Load
Load
Load
Load
Load
Load
9