-12-
No.PS※※-OMU0006-A
Term
Definition
E
Error displayed
The code number displayed, identifying the error detected by the
self-diagnosis function of the pressure switch.
Refer to "Error indication function" on page 74 for details of the errors.
Error output
Switches the switch output to ON/OFF when an error is displayed.
Refer to "List of output modes" on page 33 for operating conditions.
Refer to "Error indication function" on page 74 for details of the errors.
F
F.S.
(full span/full scale)
Abbreviation of full span and full scale; difference between the minimum and
maximum rated pressure values. means the maximum fluctuation range of
the pressure switch rated value.
For example, when the rated pressure range is -0.100 to 1.000 [MPa]:
F.S. = 1.000 - (-0.100) = 1.100 [MPa]
(Reference: 1%F.S. = 1.100 x 0.01 = 0.011 [MPa])
Fine adjustment mode
Refer to "Display value fine adjustment (function)".
Fluid contact part (or wetted
part)
Part of the pressure switch which contacts detected fluid. Pressure sensor,
seal and fitting are included.
Function selection mode
A mode in which setting of functions is performed. It is a separate menu from
the pressure setting. If any function settings need to be changed from the
factory default, each setting can be selected with "F".
The setting items are: operation mode, output type, display color, digital filter,
use of auto preset, analog/auto shift/copy, display value fine adjustment, sub
screen display, display resolution, use of power saving mode and use of
security code.
H
Hysteresis
Difference between the points at which the pressure switch is turned ON and
OFF.
Hysteresis mode
Refer to the "List of output modes" on page 33.
I
Insulation resistance
Insulation resistance of the product. The resistance between the electrical
circuit and the case.
K
Key-lock function
Function that prevents changes to the settings of the Pressure switch
(disables button operation).
L
Load impedance
Refer to "Max. load impedance".
M
Manual setting
Manual pressure setup without using auto preset.
This term is used to distinguish between manual and auto preset pressure
setup.
Master Pressure switch
A Pressure switch whose settings are copied when using the copy function.
Maximum applied voltage
The maximum voltage that can be connected to the output of an NPN device.
Maximum load current
The maximum current that can flow to the output (output line) of the switch
output.
Max. (Min.) load impedance
The maximum (minimum) load (resistance value and impedance) which can
be connected to the output (output wire) of the analog current output.
Measurement mode
Operating condition in which pressure is being detected and displayed, and
the switch function is working.
Min. setting unit
Refer to "digit".
N
Normal output
One of the switch output types. In hysteresis mode the switch output is turned
ON when pressure equal to or greater than the switch output set value is
detected. In window comparator mode, the switch output is turned ON when
pressure between the switch output set values (P1L to P1H) is detected.
(Refer to the "List of output modes" on page 33.)