-30-
No.PS※※-OMU0006-A
[F 0] Units selection function
This setting is only available for models with the units selection function.
The unit that can be displayed is different depending on the pressure range.
(kPa/MPa can still be selected if the product does not have the units selection function.)
<Operation>
Press the or button in function selection mode to display [F 0].
Press the button. Move on to display unit selection.
Press the button to set. Return to function selection mode.
[F 0] Units selection function completed
Available display unit and minimum set value
Unit
ZSE20BF
ZSE20B
ISE20B
MPa
0.001
0.001
0.001
kPa
0.1
0.1
1
kgf/cm
2
0.001
0.001
0.01
bar
0.001
0.001
0.01
psi
0.02
0.01
0.1
InHg
0.1
0.1
-
mmHg
1
1
-
Display unit selection