34
Limescaleinboiler
ensurethatthesoftenerisworking
properly(ifinstalled).
‐Checkthatthefilterofthehose
insertedintherinseaidtankisnot
fouled.
INADEQUATERINSING
Rinseaidunsuitableornot
beingdeliveredcorrectly.
Rinsingtemperaturetoolow
Checkcontainerofrinseaidand
whetheritissuitableforthetype
ofmainswater.
Checkboilertemperaturesetting
Iftheproblempersists,contactthe
aftersalesservice.
DISHESNOTPROPERLYDRIED
Rinseaidunsuitableornot
beingdeliveredcorrectly.
Waterhardnessabove12°dF
orlargeamountsofdissolved
salts
Checkcontainerofrinseaidand
whetheritissuitableforthetype
ofmainswater.RestoreTStopON
and/orconnecttheappliancetoa
hotwatersupply.
Iftheproblempersists,contactthe
aftersalesservice.
STAINSONGLASSESAND
CUTLERY
Drainhoseincorrectly
positionedorpartially
obstructed.
Checkthatthedishwasherdrain
hoseandrainareunobstructed
andthedrainisnottoohighup;
seeconnectiondiagram.
WATERINTANKAFTERPUMP
OUT
Drainhoseincorrectly
positionedorpartially
obstructed.
Checkthatthedishwasherhose
anddrainareunobstructedand
thedrainisnottoohighup;see
connectiondiagram.
13 MALFUNCTIONS SHOWN ON THE DISPLAY (FOR
THE USER)
Thedishwasherisabletoidentifyanumberofmalfunctionsandshowthemonthedisplay.
If the problem persists after thedishwasher has been switched off and back on, proceed as described
below:
(TOALLOWTHEAFTERSALESSERVICETOTAKETHEAPPROPRIATEACTION,ALWAYSMAKEANOTEOF
THEERRORINDICATED)
Err01
Theantifloodingsystemhasbeen
activated(fortherelevantmodels
only).
ContacttheAfterSalesService.
Err04 Tanktemperatureprobemalfunction ContacttheAfterSalesService
Err05 Tankwaterfillingmalfunction
Checkthatthewaterintaketapisonandthe
dynamicpressureinintakesystem,inspectwater