3
33
FlashRunner Cube User’s Manual
Programming Commands
Syntax
#load l <driver> -m <manufacturer> -d <device>
#dev o begin
#dev o end
#dev o set p <parameter> -v <value>
#conf o begin
#conf o end
#conf o set p <parameter> -v <value>
#prog o begin
#prog o end
#prog o cmd c pps -v <pps value>
#prog o cmd c connect
#prog o cmd c disconnect
#prog o cmd c unprotect
#prog o cmd c erase m <mem type> -t <tgt addr> -l <len>
#prog o cmd c blankcheck m <mem type> -t <tgt addr> -l <len>
#prog o cmd c program m <mem type> -s <src addr> -t <tgt addr> -l <len>
#prog o cmd c verify v <ver mode> m <mem type> -t <tgt addr> -l <len>
#prog o cmd c read m <mem type> -s <dst addr> -t <tgt addr> -l <len>
Parameters
<driver> Filename of the .wnd driver.
<manufacturer> Target device’s silicon manufacturer.
<device> Target device code.
<parameter> Target parameter to set.
<value> Value of the corresponding parameter.
<pps value> on or off.
<mem type> Target memory type.
<tgt addr> Target start address.
<len> Data length.
<src addr> Source (buffer) start address.
<ver mode> Verify mode: read or chks.
<dst addr> Destination start address.
Description
Perform various programming settings and operations on the target device.