Commands
3
36
System Commands
Syntax
#sys –o set –p br –v <baud rate>
#sys –o get –p br
#sys –o get –p sn
#sys –o get –p ver –v <code>
#sys –o set –p lliop –s <prj sel> -f <prj filename>
#sys –o get –p lliop –s <prj sel>
Parameters
<baud rate> 9600, 19200, 38400, 57600, 115200, or 230400.
<code> sys or driver.
<prj sel> Project number, as selected by the PRJ_SEL[5..0] lines
on the Low-Level Interface connector.
<prj filename> Project file associated to <the prj sel> setting.
Description
Set or get instrument’s internal parameters.
Examples
Sets a new serial baud rate:
#sys -o set –p br –v 115200
>
Retrieves the instrument’s serial number:
#sys -o get -p sn
00100>
Associates the project test.wnp to the project number 1:
#sys –o set –p lliop –s 1 -f \projects\test.wnp
>
http://smh-tech.com.cn sales@smh-tech.com.cn +86-15250087885