14. Type designation
ME
Single-phase electronic meter
MT
Three-phase electronic meter
371
With built-in DLC modem
372
With built-in GSM/GPRS modem or RS485
D1
Terminal block: Imax=85 A (DIN 43857)
D2
Terminal block: Imax=120 A (DIN 43857)
D3
Terminal block: Imax=100 A (BS 5685)
T1
Terminal block up to 6 A
A4
Active energy measurement, accuracy class 1 (MID B)
A5
Active energy measurement, accuracy class 2 (MID A)
1 Energy measurement in one direction
2 Energy measurement in two directions
4 Absolute measurement ΙAΙ
R5
Reactive energy measurement, accuracy cl. 2
R6
Reactive energy measurement, accuracy cl. 3
1 Energy measurement in one direction
2 Energy measurement in two directions
S6
Apparent energy measurement, 3.0%
3
S = ( P
2
+ Q
2
)
1/2
V Low voltage passive transistor input
1 No. of inputs
2 Control voltage is phase voltage
B High voltage output – relay type
1 One relay contact output
1 Relay contact output with make contact
G
Low voltage output
N Number of outputs (n=1, 2)
2 Transistor output
P Integrated switching device
1 Phase disconection
L High voltage output – Optomos type
1 One control output
1 Control output with make contact
M
Internal clock
2 Back-up power supply – super capacitor
3 Back-up power supply - Li- battery
K Communication interface
0 Optical interface in compliance with IEC62056-21
3 RS485 communication interface
4 DLC communication interface
a GPRS modem
g M-Bus communication interface
Z Load-profile