Introduction
1-15
Specifications
Power Supply
Input Voltage 115VAC or 230VAC
Watts 575
Shipping Weight
41.9 lbs (19 kg)
Dimensions
Height 16.50" (423 mm)
Width 12.75" (326 mm)
Depth 22.88" (586 mm)
Measurements
Range/Resolution Accuracy
CO 0.000–9.999 ±3%
10.00–14.00 ±5%
CO
2
0.00–18.00 ±5%
HC 0–2000 ±3%
2000–5000 ±5%
5000–9999 ±5%
O
2
0.00–25.00 ±5%
NO 0–5000 ±5%
RPM 0–9999 ±0.5%
°C -10–150 ±5%
°F 14–302 ±5%
Lambda (λ) 0.500–2.000 (calculated)
AFR 5.00–25.00 (calculated)
Operating Conditions
Maximum ambient temperature
113 °F (+45 °C)
Minimum ambient temperature
35.5 °F (+2 °C)
Relative humidity
Up to 90%, non condensing
Maximum atmospheric pressure variation
10.15–15.95 psi (700–1100 mbar).
Warm-up Time
One minute
Propane Equivalence Factor (P.E.F.)
P.E.F. value 0.530