Control Box / ControlTechManager Control Mode Instrument Behavior
Set Headlength Behavior
1. Change the Set Headlength Unit on the Control Box and or the ControlTechManager
Qualifier Menu to inches.
2. When in Control Mode executing Parameters from the PC ControlTechManager or
Control Box when using interchangeable head style instruments with a Snap-on “A”
suffix torque adapters, the Parameter Headlength field is shown as 0 (zero). The Control
Box interprets 0 (zero) as the default calibrated length on J, Y, X and Z shank
Interchangeable Heads Instruments.
3. When adding a crows-foot adapters or any other adapter type to an interchangeable
head instrument that already has Snap-on “A” suffix adapter attached, the total
combined effective length of crows-foot adapter and Snap-on “A” J, Y, X and Z adapters
must be inputted on the Parameter Control Box and or PC ControlTechManager SET
HEADLENGTH field.
4. When in Control Mode there is no rounding effect on the Control Box or
ControlTechManager Set Headlength Fields. See example in Figure 2 (head / offset
reference).
5. Standard ratcheting head instruments the set headlength calibration default is always 0
(zero) regardless of the torque range or ratchet drive size. Only a crows-foot adapter
effective length needs to be inputted. See example in Figure 3 (offset reference).