100
Scope Multimeter Operations Operations
z To adjust trace controls:
1. Select Setup from the Scope Multimeter toolbar.
The Scope Multimeter Preferences dialog box opens
2. Double tap Traces to open the submenu.
3. Select the tab for the trace to be configured from the submenu
The traces dialog box displays (Figure 9-9).
1— Trace tabs
2— Trace Probe button
3— Trace Scale button
4— Trace characteristics check boxes
5— Baseline position
6— Auto Find button
7— OK button
Figure 9-9 Traces dialog box
4. Select the Trace Probe button to open the menu.
5. Highlight a probe on the list and tap OK close the window.
6. Select the Trace Scale button to adjust the vertical scale, of the display.
A dropdown menu opens, menu options vary depending upon which test lead is selected.
7. Select a trace scale option, then close the window.
8. Select or deselect the trace characteristic items as needed:
– Displayed—this trace is on screen when checked, and not visible when not checked.
– Inverted—signal polarity is reversed when checked, normal when not checked.
– Coupling AC—check when sampling an AC signal, do not check for DC signals.
– Peak Detect—use when trying to capture a fast event or signal glitch.
9. The scope samples the signal and internally calculates the best scale to fit the signal pattern
on the screen when Auto Find is selected. If run on the same channel as the trigger, the
trigger value is set halfway between the minimum and maximum values of the waveform.
10. The baseline position is the zero line of the trace, use the slider and arrows to adjust it.