EasyManuals Logo

socomec MASTERYS IP+ User Manual

socomec MASTERYS IP+
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
MASTERYS IP+
40-60 kVA 3/1
ENGLISH
IOMMASIPXX07-GB 02
51
TECHNICAL SPECIFICATIONS
12
Models
Input/Output phases 3/1
Electrical speci cations - Input
Mains voltage 3P+N 400 V ±20% (up to -35% @70% of nominal load)
Input frequency 50-60 Hz ±10%
Input power factor 0,99
THDI < 10%
Standards
Safety EN 62040-1-1, EN 60950-1
Type and performance EN 62040-3 (VFI-SS-111)
EMC EN 62040-2
Product certi cation
Protection level IP31
Electrical speci cations - Output
Output voltage (P+N) 230 V single phase (selectable: 208*/220/230/240 V) ±1%
Frequency 50-60 Hz ±2% (from 1% to 8% if generator is used)
Automatic bypass nominal output voltage ±15%
(from 10% to 20% selectable if generator is used)
Nominal power 40 kVA: 32 kW
60 kVA: 48 kW
Overload on mains power supply 125% 10 minutes
150% 1 minute
Crest factor 2.5:1
Voltage distortion 1% with linear load
* @ Pout = 90% Pnom
Environment
Operating temperature 0÷40 °C (15÷25 °C recommended for longer battery life)
Storage temperature -5÷45 °C
Relative humidity 0÷95% condensation-free
Protection level IP31
Max. altitude 1.000 m (3.300 ft) without derating; 3.000 m (10.000 ft) max
Acoustic noise (dB) < 62
Required cooling capacity (m
3
/h) 1810
Dissipated power max 40 kVA: 3800 W
60 kVA: 5500 W
Dissipated power 40 kVA: 13100 BTU/h
60 kVA: 18800 BTU/h
1000
835
1.400
Weight:
- 40 kVA: 490 kg
- 60 kVA: 540 kg