2
Remove all of the screws from the cover plates and the cable entry knockouts
shown in Figure 10-10 and Figure 10-11.
NRT3-OP-MBP
(Figure 10-10)
WARNING:
OPENING THIS COVER PLATE WILL CAUSE
INVERTER SHUTDOWN.
ONLY AUTHORIZED SERVICE PERSONNE L
CAN OPEN AND OPERATE IT.
MANUAL BYPASS SWITCH
TO UPS OUTPUT
L N
TO UPS INPUT
L N
TO UPS PARALLEL TO UPS PARALLEL
INPUTOUTPUT
OUTPUT SOCKET-2
20A MAX. PER OUTLET
OUTPUT SOCKET-1
10A MAX. PER OUTLET
OUTPUT BREAKER-2
250V AC 25A
OUTPUT BREAKER-1
250V AC 20A
Screw x 4
Cable Entry Knockout x 2
NRT3-OP-PMB
(Figure 10-11)
TO UPS PARALLEL
TO UPS PARALLEL
TO UPS-1 OUTPUT
BYPASS MODE
UPS MODE
UPS-2UPS-1
OUTPUT BREAKERBYPASS BREAKER
WARNING:
ONLY AUTHORIZED SERVICE PERSONNEL
CAN REMOVE THIS COVER PLATE.
REMOVING THIS COVER PLATE WILL CAUSE
THE INVERTER TO SHUTDOWN. SEE THE
USERS MANUAL FOR INSTRUCTIONS.
Screw x 8
Cable Entry Knockout x 2
TO UPS-1 INPUT
TO UPS-2 OUTPUT
TO UPS-2 INPUT
INPUT
OUTPUT
N L
N L
N L
N L
3
Follow Figure 10-12 and Figure 10-13 to install the provided accessories on
the Manual Bypass and perform wiring. The suggested knockout or hole diameter
for optional cable gland is 34.5mm (1-23/ 64 inch).
NRT3-OP-MBP
(Figure 10-12)
WARNING:
OPENING THIS C
INVERTER SHUTDOWN.
ONLY AUTHORIZED SERVICE PERSONNEL
CAN OPEN AND OPERATE IT.
T
O
UP
S
P
A
R
A
LL
E
L
T
O
U
P
S
P
A
R
A
LL
E
L
L
N
OUTPUT BREAKER-1
250V AC 20A
OUTPUT BREAKER-2
250V AC 25A
OUTPUT SOCKET-2
20A MAX. PER OUTLET
OUTPUT SOCKET-1
10A MAX. PER OUTLET
I
N
P
U
T
O
U
T
P
U
T
L
N
P
1
D
R
Y
C
O
NT
A
C
T
P
4
P
3
P
2
R
E
P
O
R
S
-
4
85
R
S
-
23
2
SMART SLOT
P
A
R
A
L
LE
L
P
A
R
A
L
LE
L
-
T
M
O
V
I
N
P
U
T
Standoff
× 4
( 6 )
4
M3 Screw
× 4
( 4 )
Wire × 2 ( )
Cable Gland × 2
optional
UPS
1
9
MBP
OUTPUT
L
N
L
AC INPUT
N

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the socomec NRT3-U5000 & NRT3-U5000C & NRT3-U7000 & NRT3-U7000C & NRT3-U7000CLA and is the answer not in the manual?

socomec NRT3-U5000 & NRT3-U5000C & NRT3-U7000 & NRT3-U7000C & NRT3-U7000CLA Specifications

General IconGeneral
Brandsocomec
ModelNRT3-U5000 & NRT3-U5000C & NRT3-U7000 & NRT3-U7000C & NRT3-U7000CLA
CategoryUPS
LanguageEnglish

Related product manuals