(parallel/independent mode) Settings
for the inverter. If not, change the PV
input mode.
Check whether the CT wiring is
correct.
Input reverse
connection fault
Battery temperature
protection
Make sure the inverter is installed
where there is no direct sunlight.
Please ensure that the inverter is
installed in a cool/well ventilated
place.
Ensure the inverter is installed
vertically and the ambient temperature
is below the inverter temperature
limit.
Radiator 1 temperature
protection
Radiator 2 temperature
protection
Radiator 3 temperature
protection
Radiator 4 temperature
protection
Radiator 5 temperature
protection
Radiator 6 temperature
protection
Ambient temperature 1
protection
Ambient temperature 2
protection
Module 1 temperature
protection
Module 2 temperature
protection
Module 3 temperature
protection
Unbalanced bus voltage
RMS
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then
switch ON inverter. Check whether the
problem is solved.
If no, please contact technical support.
The transient value of
bus voltage is
unbalanced
Busbar undervoltage
during grid-connection
Check whether the PV series voltage
(Voc) is higher than the maximum