SE2500H SE3000 SE4000H SE5000H SE6000H SE8000H SE10000H Units
INSTALLATION SPECIFICATIONS
AC output conduit size / Wire cross section 19-25 mm / 1-13 mm
2
DC input conduit size / # of strings / Wire cross
section
19-25 mm / 1-2 strings / 1-13 mm
2
19-25 mm / 1-3 strings
/ 1-13 mm
2
AC Terminal Block Cross Section 1-13 mm
2
Dimensions with Safety Switch (HxWxD) 450 x 370 x 174 540 x 370 x 185 mm
Weight with Safety Switch 10 11.4 11.9 17.6 kg
Cooling Natural Convection
Operating Temperature Range
(1)
-40 to +60 °C
Noise < 25 < 50 dBa
Protection Rating IP65 - Outdoor and Indoor
Recommended circuit breaker/ fuse size to use at the connection point of the SolarEdge inverter to the grid:
Inverter Maximum output current (A) Minimum fuse rating (A)
Maximum fuse rating (A)
SE2500H 12.5 16 50
SE3000H 16 20 50
SE4000H 18.5 25 50
SE5000H 23 32 50
SE6000H 27 40 50
SE8000H 48 63 80
SE10000H 48 63 80
(1)
Full power up to at least 50°C. For power de-rating information refer to: https://www.solaredge.com/sites/default/files/se-temperature-derating-note.pdf
3
Single Phase Inverters with HD-Wave
Technology
Specifications
(Australia)
MAN-01-00538-1.0