Operation MethodOperation Method
i) Mppt Scan Mode
There are four modes to be selected. , , , Off LowFreqScan MidFreqScan High
FreqScan. It shows the frequence of PV panel scan.
If LowFreqScan is selected, the inverter will scan the PV panel by low
frequence.
Mppt Scan Mode
Mode Select
>Off<
j) Reset Energy
The user can clear the power energy by this function.
k) Reset Meter
The user can clear the meter energy by this function. Press “Up or “Down button
to select and long press “Down to confirm. (The user can select Yes” to reset
meter if the user uses meter.)
l) Reset Errorlog
The user can clear the errorlogs by this function. Press “Up or “Down button to
select and long press “Down to confirm.
Mode Select
>YES/NO<
Reset Energy
Reset
>YES/NO<
Reset Meter
Reset
>YES/NO<
Reset Errorlog
m) Reset WiFi
The user can restart the WiFi by this function.
Reset
>YES/NO<
Reset WiFi
n) Machine Type
The user can check the Machine Type by this function.
15.0-T
Machine Type
There are three functions(Disable/Manual/Smart Save) which can be selected for
Load Management. Disable means the heat pump is off. When Manual is
selected the user can control the external relay to remain close or open manually.
Smart Save mode can set the values of the heat pump’s on/off time and
conditions, operating modes.
If the user uses the inverter dry contacts to control heat pump through Adapter
box, please refer to the Adapter Box Quick Installation Guide to set the
parameters here.
>Load Management<
Dry Contact
Load Management
Disable/Manual/Smart Save
Enter
Back
o) PV Connection
The user can select the PV connection type by this function.
Mode Select
Mode Select
> Multi/Comm <
PV Connecon
Machine Type
Load Management
p) Dry Contact
The user can use the Dry Contact to connect SG Ready heat pump by this
function via Adapter Box.