EasyManuals Logo

Solcon RVS-DN User Manual

Solcon RVS-DN
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #2 background imageLoading...
Page #2 background image
Table of Contents
Page Subject Appendix Page Subject
1 Starter Selection 39 Table of content
2 Installation 40 UL and cUL instructions, LR recommendations
3 By-pass contactor 41 Fuse selection
4 - 6 Control terminals 42 Motor and Starter Fault Occurrence Timing Table
7 Control terminals – Option Boards 43 Warranty claim sheet & Fault Inquiry
8 Control Wiring 44 Inside Delta Description
9-11 Wiring Diagrams 45 Overload Trip Time (Approximate calculation)
12-13 Wiring Diagrams – Communication 46-50 Dimensions and Weights
14 Wiring Diagrams – Diesel Generator 51 Block Diagram and Notes
15 Wiring Diagrams – Brake motor 52 Ordering Information
16-17 Internal setting
18-19 Start and stop parameters
20-21 Motor and starter protection
22-23 Front panel and LCD Displays
24 Display mode and Default Parameters
25-30 Parameter setting
31-32 Start-up and Pump Control adjustments
33-34 Menu Description
35-36 Trouble shooting
37-38 Technical specification
Safety
Read this manual carefully before operating the equipment and follow its instructions
Installation, operation and maintenance should be in strict accordance with this manual,
national codes and good practice. Installation or operation not performed in strict
accordance with these instructions will void manufacturer’s warranty.
Disconnect all power inputs before servicing the soft-starter and/or the motor.
After installation, check and verify that no parts (bolts, washers, etc) have fallen into the
power Section (IP00 for sizes B-G).
Attention
This product was designed for compliance with IEC 947-4-2 for class A equipment.
RVS-DN 8 - 820 are UL approved. RVS-DN 950 - 3500 are designed to meet UL requirements.
RVS-DN 8 - 1400 are LR approved. RVS-DN 1800 - 3500 are designed to meet LR requirements.
Use of the product in domestic environments may cause radio interference, in which case, the user may be
required to employ additional mitigation methods.
Utilization category is AC-53a or AC53b. Form1. For further information, see Technical Specifications for
further details.
Warnings
Internal components and P.C.B’s are at main potential when the RVS-DN is connected to main.
This voltage is extremely dangerous and will cause death or severe injury if contacted.
When RVS-DN is connected to main, even if control voltage is disconnected and motors is
stopped, full voltage may appear on starter’s output and motor’s terminals.
Unit must be grounded to ensure correct operation, safety and to prevent damage.
Check that Power Factor capacitors are not connected to the output side of the soft starter.
The company reserves the right to make any improvements or modifications to its products without prior notice
.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Solcon RVS-DN and is the answer not in the manual?

Solcon RVS-DN Specifications

General IconGeneral
BrandSolcon
ModelRVS-DN
CategoryController
LanguageEnglish

Related product manuals