39
Alarm Meaning Solution
Display shows: OP The appliance indicates that
the steaming knob should be
open during the descaling
function.
Put the steam wand into
a container and rotate the
steaming knob anticlockwise.
Display shows: CL The appliance indicates that
the steaming knob should be
closed during the descaling
function.
Put the steam wand into
a container and rotate the
steaming knob clockwise.
Display shows: H2O The water level in the water
tank is too low.
Rell the water tank.
Display shows: S/M/H S, M, and H show the
selected water hardness. (s:
soft, m: medium, h: hard).
Use a test strip to measure
the water hardness and set
the appliance accordingly.
Steaming function
button ashes red
The appliance needs to be
descaled.
See section Descaling.
Double cup extraction
button ashes white
and red
The appliance needs to be
cleaned with a cleaning
tablet.
See section Using the brewing
head cleaning cycle.
Single cup extraction
button ashes white
and red
The water lter cartridge
needs to be replaced,
See section Replacing the
water lter cartridge.
Both cup extraction
buttons are ashing
and an alarm is audible
Water tank is empty. Fill the water tank.
The coee is ground too ne. Change the grind size.
V HELPLINE
This item stands out due to its long-life cycle and reliability. Despite this though, if a
malfunction ever occurs, simply give us a call. Often a breakdown can be easily and
quickly remedied with the right tip or technique without having to straight away send
o the device for repair. We will give you all the advice and practical support you require.
Live chat on: www.seattlecoeegear.com
E-Mail: support@seattlecoeegear.com
Phone: 866-372-4734
Keep the original packaging in a safe place so that you may use it in the event that
transportation or shipping of the product becomes necessary.