Safety Instructions
WARNING
1. 120 Volts may cause serious injury from electric
shock. Disconnect electrical power before starting
installation or servicing. Leave power disconnected
until installation/service is completed.
2. Sharp edges may cause serious injury from cuts. Use
care when cutting plenum openings and handling
duct system.
3. Dropping may cause personal injury or equipment
damage. Handle with care and follow installation
instructions.
CAUTION
1. Read all instructions before beginning installation.
2. Improper installation may cause property damage or
injury. Installation, service, and maintenance must be
performed by a qualied service technician.
3. Do not use in pool applications. Pool chemicals can
damage the dehumidier.
4. Do not use solvents or cleaners on or near the
circuit board. Chemicals can damage circuit board
components.
5. Wait 24 hours before running the unit if it was not
shipped or stored in the upright position
6. Do not use dehumidification to prevent window
condensation in the winter. During the winter the
dehumidifier does not run enough to effectively
prevent window moisture. The dehumidier has a
40° dew point lower limit and the moisture level in a
home during the winter is usually below this value.
The window condensation is a result of the cold
outdoor air/window temperature. Ventilation is the
most effective and efcient means of dealing with
window condensation in the winter.
Table of Contents
Safety Instructions ............................1
Specications ................................2
Packaging Content............................2
Set Up Dehumidier for Installation ..............3
Duct Collars ...............................3
Control Location............................4
Hard Wire Modication ........................4
Electrical Specications for Hard Wiring .........4
Wiring Instructions ..........................5
Location Considerations .......................5
Suspended Installation ........................6
Drain Installation .............................6
Leveling ..................................6
Condensate Pan, Condensate Pump
and Float Switch ...........................6
Ducting to HVAC System – Basement and
Attic Installations .............................7
Ducting for Stand Alone Installations or
Non-Ducted Installations .......................7
Ducting for Two Zone Installations...............8
Lennox Control...............................9
Y6456 – External Control or Crawl
Space/Sealed Attic Control and Wiring ..........10
Wiring the Dehumidier to the HVAC System
and Zone Dampers ...........................11
System Set-up and Checkout ..................12
Installer Test Mode.........................14
Start Up and Sequence of Operation ............15
Single Zone Whole House or Stand Alone
Using the Dehumidier Control ...............15
Single Zone Whole House or Stand Alone
Using an iComfort
®
Thermostat or
Y6456 External Control .....................15
Crawl Space or Sealed Attic (Remote) Control
Using Y6456..............................15
Two Zone – Primary and Secondary ...........15
Ventilation ..................................16
Installation & Wiring ........................16
Vent Auto & Vent-Timed.....................16
Outdoor Temperature Sensor Installation .......17
Determine Ventilation Requirements ...........17
Installer Settings ..........................18
Sequence of Operation .....................19
Troubleshooting .............................19
Table 4 – Error Codes ......................20
Table 5 – Troubleshooting Guide ..............21
Wiring Schematics ...........................22
Service Parts................................23
1
DEHUMIDIFIERS
507386-02
8/2018
Supersedes 1/2017
HEALTHY CLIMATE
®
DEHUMIDIFIERS
INSTALLATION INSTRUCTIONS FOR HEALTHY CLIMATE
®
DEHUMIDIFIER
MODEL HCWHD3-070, HCWHD3-095 AND HCWHD3-130
READ COMPLETE SAFETY INSTRUCTIONS AND INSTALLATION INSTRUCTIONS BEFORE STARTING
Question and Answer IconNeed help?

Do you have a question about the Solutions HCWHD3-070 and is the answer not in the manual?

Summary

Safety Instructions

Specifications and Packaging

Dehumidifier Setup and Duct Collars

Duct Collar Installation

Guidance on attaching duct collars for fully ducted and non-ducted installations.

Control Location and Hard Wiring

Control Location Adjustment

Procedures for moving the on-board control to the front panel.

Hard Wire Electrical Specifications

Details electrical requirements and specifications for hard wiring the unit.

Wiring and Location Considerations

Wiring Instructions

Step-by-step guide for connecting electrical service to the dehumidifier.

Installation Location Requirements

Guidelines for selecting an optimal installation location, considering airflow and access.

Installation Methods and Drainage

Suspended Installation Guide

Instructions for hanging the unit using threaded rods and unistruts.

Unit Leveling Procedure

How to adjust the leveling feet for proper drainage and unit stability.

Condensate Pan and Float Switch

Requirements for condensate pans, pumps, and float switch wiring.

Ducting for HVAC and Standalone

Ducting to HVAC System

Preferred installation method for basement and attic connections to the HVAC return.

Standalone Ducting

Guidelines for ducting the unit for dehumidifying a specific area independently.

Two Zone Ducting Installation

External Control and Thermostat Integration

Y6456 Control and Wiring

Y6456 External Control Wiring

Wiring diagram and instructions for using Y6456 as an external control.

Y6456 Crawl Space;Sealed Attic Control

Wiring and setup for Y6456 used as a wired remote control.

HVAC and Zone Damper Wiring

Wiring to HVAC System

Connecting the dehumidifier to the HVAC for integrated operation and ventilation.

Wiring to Zone Dampers

Connecting zone dampers for multi-zone dehumidification control.

System Setup and Ventilation Configuration

System Setup and Checkout

Guide to perform system checkout and verify installation.

Ventilation Mode Settings

Configure ventilation modes (Timed, Auto-B, C, D) and time settings.

Remote Control Setup

Enable and configure settings for remote control operation.

Advanced Configuration Options

Zone Configuration Settings

Select single or two-zone operation for the dehumidifier.

Dehumidification with Air Conditioning

Configure dehumidifier behavior when the air conditioner is active.

External Control Configuration

Enable or disable external control interface for dehumidifier operation.

Humidity Offset Adjustment

Apply an offset to the on-board humidity reading for calibration.

Installer Test Mode

Dehumidification Only Test

Test sequence for dehumidification functionality without zoning or ventilation.

Zoning and;or Ventilation Test

Test sequence for zoning and ventilation features, including damper operation.

Start Up and Operation Sequences

Single Zone Operation (Dehumidifier Control)

Sequence for single-zone operation using the dehumidifier's on-board control.

Single Zone Operation (External Control)

Sequence for single-zone operation using external thermostats or Y6456.

Remote Control Operation (Y6456)

Operation sequence for crawl space/sealed attic control using Y6456.

Two Zone Operation

Sequence for controlling humidity in primary and secondary zones.

Ventilation System

Ventilation Installation and Wiring

Guide to installing and wiring the ventilation damper and related components.

Ventilation Mode Selection

Details on Vent-Timed and Vent-Auto modes (B, C, D) for fresh air intake.

Ventilation Planning and Requirements

Outdoor Temperature Sensor Installation

Instructions for mounting the outdoor temperature sensor correctly.

Calculating Ventilation Airflow

Method to calculate minimum ventilation requirements based on house size and bedrooms.

Determining Fresh Air Delivery

How to estimate airflow based on duct type, length, and static pressure.

Ventilation Cycle Time and Installer Settings

Determining Ventilation Cycle Time

Using tables to find the correct cycle time based on CFM required and delivered.

Installer Settings Configuration

Guide to configuring installer settings for ventilation and other functions.

Operation Sequences and Troubleshooting

Sequence of Operation Details

Describes how the dehumidifier operates in different modes and scenarios.

Troubleshooting and Error Codes

Guidance on identifying and resolving common issues and error codes.

Wiring Schematics

Service Parts (Models HCWHD3-070;095)

Service Parts (Model HCWHD3-130)

Solutions HCWHD3-070 Specifications

General IconGeneral
BrandSolutions
ModelHCWHD3-070
CategoryOther
LanguageEnglish

Related product manuals