EasyManua.ls Logo

SOMFY Connect User Manual

SOMFY Connect
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1 3/27/2015
Somfy Connect
#1870210
Control SOMFY RTS and SDN Motors using Lutron’s:
Radio RA2 (RA2)
Homeworks QS (HWQS)
Grafik Eye QS (GEQS)
Quantum
The Somfy Connect is configured using a software
application which requires a USB to RS485 adapter such as
Somfy Part Number 9015260 or equivalent
.

Other manuals for SOMFY Connect

Question and Answer IconNeed help?

Do you have a question about the SOMFY Connect and is the answer not in the manual?

SOMFY Connect Specifications

General IconGeneral
BrandSOMFY
ModelConnect
CategoryRecording Equipment
LanguageEnglish

Summary

Somfy Connect Connector Overview

DC Jack Specifications

Details the DC power input specifications for the Somfy Connect, including voltage and current.

DB9 Connector for RS232 Input

Describes the DB9 port used for RS232 input from Lutron Main Repeaters or NWK devices.

RJ45 Connector for RS485

Explains the RJ45 port for RS485 connections to SDN or URTSI devices.

General Somfy Connect Information

Manual Control Types

Outlines the three types of manual control: Single, Sequence, and Group operations.

Storage Capacity Details

Specifies the number of button presses, timed, sunrise, and sunset events the Connect can store.

HomeWorks QS Integration Requirements

Details specific requirements when using the Somfy Connect with HomeWorks QS systems.

Lutron Control Options for Somfy Connect

Single and Sequence Control

Explains how push-buttons can be assigned single functions or sequence control for motors.

Group Control Operation

Describes the 2-button operation for Group Control with specific Lutron devices like Keypads.

Somfy Connect Hardware Requirements

Required Additional Peripherals

Lists necessary components like USB to RS485 adapter, Cat 5 cable, and URTSI.

Connection Ports Overview

Details the RJ45 and DB9 connectors on the Somfy Connect for networking and communication.

Powering the Somfy Connect

Explains power sources and delivery methods for RTS and SDN applications.

Baud Rate Configuration for NWK

Specifies the required baud rate setting for the Main Repeater or NWK for communication.

Typical Somfy Connect Hardware Configurations

Radio RA2 to RTS System Diagram

Illustrates the hardware setup for controlling Somfy RTS motors via Lutron Radio RA2.

Radio RA2 to SDN System Diagram

Illustrates the hardware setup for controlling Somfy SDN motors via Lutron Radio RA2.

Power and Connection Notes

Provides essential notes on power options and low-voltage connections for typical setups.

System Integration Setup Examples

Radio RA2 to RTS Setup Example

Visualizes the typical hardware configuration for Radio RA2 to RTS integration.

Radio RA2 to SDN Setup Example

Visualizes the typical hardware configuration for Radio RA2 to SDN integration.

Programming Somfy Connect for RTS via URTSI

Driver and Software Installation Steps

Steps for installing necessary drivers and the Somfy Connect configuration software.

Initial Software Screen and COM Port

Details the first screen of the software and the process of selecting the COM port.

Verifying Communication Link

Explains how to check for a successful communication link before proceeding with programming.

Programming Somfy Connect for RTS via URTSI

Understanding Configuration Settings Frames

Explains the configuration frames indicating Somfy Connect setup details and memory.

Initiating Command Mapping Process

Describes the process of starting command mapping by clicking 'Listen' in the software.

Listen Mode Behavior and Timeout

Details the 'Listening' state, its visual cues, and timeout behavior during mapping.

Programming Somfy Connect for RTS via URTSI

Lutron Input Format for RA2/HWQS/Quantum

Explains the expected input format for RA2, HWQS, and Quantum Lutron devices.

Lutron Input Format for Grafik Eye QS

Explains the expected input format for Grafik Eye QS Lutron devices.

Handling Corrupted Lutron Input

Provides guidance on what to do if Lutron input is corrupted during the mapping process.

Programming Somfy Connect for RTS via URTSI

Inputting the URTSI String for Mapping

Describes how to input the URTSI string, including address and channel, for command mapping.

Saving Mapped Data

Explains the process of saving mapped data using 'Save Single', 'Save Sequence', or 'Save Group'.

Testing Captured Commands

Details how to test the saved commands by activating Lutron push-buttons in RUN mode.

Programming Somfy Connect for RA2 to SDN

SDN Configuration Screen Overview

Introduces the screen for configuring Somfy Connect for RA2 to SDN integration.

Specifying Single Motor or Group Address

Guides on entering the Single Motor or Group Address and clicking 'Calculate'.

Choosing SDN Command for Functions

Explains how to select commands for Single, Sequence, or Group functions in SDN.

Programming Somfy Connect for RA2 to SDN

Saving SDN Single Function Example

Illustrates the process of saving a Single Function UP command for an SDN device.

Testing Programmed SDN Commands

Details testing the programmed SDN commands by activating Lutron push-buttons.

Managing Somfy Connect Data

Data Saving Functions Explained

Explains how 'Save' commands store map#, Lutron input, and command data.

Data Retrieval Functions Explained

Describes how 'Get' commands retrieve and display saved data from the Somfy Connect.

Data Clearing and Deletion Functions

Explains 'Clear' commands for deleting specific data sets or all data except coordinates.

Screen Clearing and Print Utility

Details 'Clear Screen' for the text box and 'Print' for record keeping and future reference.

Configuring Somfy Connect Defaults

Deleting Saved Maps or Scheduled Events

Describes the process for deleting saved maps or scheduled events from the Connect.

Modifying Default Configuration Settings

Guides on changing Somfy Connect version, memory size, and COM port selection.

Event Scheduling: Timed Events

Setting Timed Event Parameters

Details how to set the correct time, date, and days for timed events.

Saving Timed Event Configurations

Explains associating saved maps and saving timed event configurations.

Event Scheduling: Sunrise and Sunset Events

Setting Sunrise/Sunset Event Location

Guides on entering location or coordinates for sunrise/sunset events.

Saving Sunrise/Sunset Event Configurations

Explains associating saved maps and saving sunrise/sunset event configurations.

Setting RTS Delay for URTSI

Configuring RTS Delay Parameters

Explains the purpose and setting of RTS Delay for URTSI to prevent transmission interference.

Custom Coordinate Entry for Events

Entering Time Zone Information

Details valid entries for Time Zone based on Greenwich Meridian Time.

Entering Latitude and Longitude

Guides on entering Latitude and Longitude in degrees and minutes for event calculations.

Important Somfy Connect Usage Notes

Group Commands with Light Loads

Discusses issues with Group Commands and light loads on Lutron keypads, offering solutions.

RA2 iPhone/iPad App Integration

Explains how to use the Somfy Connect with RA2 iPhone/iPad applications for control.

NWK Ethernet Port Limitation

Notes that using the NWK Ethernet port disables the device's serial port.

Lutron Serial String Mapping Constraints

Clarifies that each Lutron serial string maps to a single map location to avoid conflicts.

Sequence Mode Push-button Behavior

Explains potential issues with multiple push-buttons controlling the same motor in Sequence mode.

Related product manuals