64
S1 User Handbook
8
SERIAL COMMUNICATION PROTOCOL
SERIAL COMMUNICATION PROTOCOL
Command Description Response
TBK:? Read Talkback Status TBK:a,b,c,d
TMR:a,b,c,d,e Congure Timers ACK:
A = Channel number.
1 = Ch 1
2 = selects Ch 2
etc
a = selects Ch 10
B = Timer 1 on Input 1
1 = Enabled
0 = Disabled
C = Timer 2 on Input 1
1 = Enabled
0 = Disabled
B = Timer 1 on Input 2
1 = Enabled
0 = Disabled
C = Timer 2 on Input 2
1 = Enabled
0 = Disabled
TMR:a? Read Channel Timer Settings TMR:a,b,c,d,e
UID: Unit Identication UID:S1-MIXER
UPD: UpdateEEPROMwithcurrentconguration PleaseWait…
If an Err:08 is received, then the command ACK:
cannot save the current conguration
because write is disabled.
Write can be enabled by sending:
EEP:1,2
VER: Firmware Version VER:x.xx-Sy.y
Where x.xx is Output board rmware version
and Sy.y is the Stereo board rmware version
Error Messages
Err:01 Command Not Found
Err:02 Missing Parameter
Err:04 Parameter out of Range
Err:06 Serial Number Write Error
Err:07 Command Not Valid in current mode
Err:08 EEPROM write is disabled
Err:09 TWI / Checksum Error

Table of Contents