1-16
27
Chapter 2 Menu
Overview
The color temperature is adjusted with the COLOR
TEMP ADJ menu. The color temperature can be set to
one of STD, COL1 or COL 2 for each channel.
Use the factory setting value or the adjusted value as
an original values to shorten the adjustment time.
Color temperature adjustment can be made in the
following three ways:
Knob adjustment
Adjust the color temperature with the bias and gain
knobs manually.
Automatic adjustment using a probe
You can use the following probes for automatic
adjustment of color temperature. Except for the Sony
BKM-14L, a cable is required to connect the color
analyzer to the monitor.
Adjusting the Color Temperature — COLOR TEMP
ADJ Menu
For more information about the cable specification required
and about the connection, see “Connection Cable
Specifications for Color Temperature Probes” on page
54.
Copying other data
Copying data from other BVM-series monitors that
have been connected via the serial remote connector,
or from data stored in monitor memory cards.
Manufacturer Probe Model Name
SONY BKM-14L (no cable required)
GRASEBY SLS 9400
MINOLTA CA-100
PHILIPS
PM 5639
THOMA TF6
28
Chapter 2 Menu
Adjusting the Color Temperature — COLOR TEMP ADJ Menu
Structure of the COLOR TEMP ADJ Menu [B]
Level 1 Level 2 Level 3 Level 4 Level 5
MANUAL [B1]
ADJUST [B211] START [B2111] SET PROBE
PROBE [B2] SONY BKM-14L [B21] ANALYZE [B212] X ON CRT
GRASEBY SLS9400 Y
MINOLTA CA-100 LOWLIGHT (20 IRE)
PHILIPS PM5639 HIGHLIGHT (100IRE)
THOMA TF6 START [B213] D65
X D93
Y SET PROBE
LOWLIGHT (20 IRE) ON THIS CRT [B2121]
HIGHLIGHT (100IRE)
D65 SET PROBE
D93 ON CRT
COPY [B3] OTHER VALUE [B31] STD
COL1
COL2
D65
D93
OTHER
MONITOR [B32] MONITOR
ADDRESS [B321] STD
COL1
COL2
MEMORY CARD [B33] FILE NAME [B331] STD
COL1
COL2
TRIM [B4] ADJUST
TRIM
SIGNAL
The lower levels of GRASEBY SLS9400, MINOLTA CA-100, PHILIPS PM5639 and THOMA TF6 are the
same as [B213] in level 3 and lower than that.