SECTION 6
6.1 Introduction
SERVICING THE
3000 WATT SYSTEM SUPPLY
This section provides general maintenance and calibration information as well as replacement
parts lists for the DCS Series (3kW) supply.
Units Under Warranty
Units requiring repair during their warranty period should be returned to the manufacturer for
service. Unauthorized repairs performed by any one other than the manufacturer during the
warranty period may void the warranty. Any questions regarding the warranty or any repairs
should be directed to the manufacturer.
WARNING
Exercise caution when using and servicing power supplies. High energy levels can
be stored at the output voltage terminals on all power supplies in normal operation.
In addition, potentially lethal voltages exist in the power circuit and the output
connector of power supplies which are rated at 40V and over. Filter capacitors
store potentially dangerous energy for some time after power is removed.
6.2
6.2.1
General Maintenance and Repair
Periodic Service
Routine service consists only of annual calibration and periodic cleaning. Whenever a unit is
removed from operation, clean it with naphtha or an equivalent solvent for the metal surfaces
and with a weak solution of soap and water for the front panel. Use low pressure compressed
air to blow dust from in and around components on the printed circuit boards.
Operation Manual 6-1

Table of Contents