Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-184-
0: A+B frequency, acceleration /deceleration of main
reference A frequency source buffering is invalid
1: A+B frequency, acceleration/ deceleration of main
reference A frequency source buffering is valid,
acceleration and deceleration are determined by
P08.04 (Acceleration time 4).
P09.14
Low-frequency
proportional gain
(Kp)
0.00100.00
Low-frequency switching point: 5.00Hz, high-frequency
switching point: 10.00Hz (P09.04 corresponds to high-
frequency parameter), and the middle is the linear
interpolation between these two points
1.00
P09.15
Acceleration/
deceleration time
of PID command
0.01000.0s
0.0s
P09.16
Filter time of PID
output
0.00010.000s
0.000s
P09.17
Reserved
P09.18
Low-frequency
integral time (Ti)
0.0010.00s
0.90s
P09.19
Low-frequency
differential time
(Td)
0.0010.00s
0.00s
P09.20
Low-frequency
point of PID
parameter
switching
0.00P09.21
5.00Hz
P09.21
High-frequency
point of PID
parameter
switching
P09.20–P00.04
10.00Hz
P09.22
P09.28
Reserved
/
/
/