Loading...
Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-229-
current loop
P23.15–
P23.19
Reserved
/
/
/
P24––Encoder of motor 2
Function
code
Name
Description
Default
value
Modify
P24.00
Encoder type
display
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
0
P24.01
Encoder pulse
number
Number of pulses generated when the encoder revolves
for one circle.
Setting range: 0–60000
1024
P24.02
Encoder direction
Ones: AB direction
0: Forward
1: Reverse
Tens: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
0x000
P24.03
Detection time of
encoder offline
fault
0.010.0s
2.0s
P24.04
Detection time of
encoder reversal
fault
0.0100.0s
0.8s
P24.05
Filter times of
encoder detection
Setting range: 0x00–0x99
Ones: Low-speed filter times, corresponds to 2^(0–
9)×125us.
Tens: High-speed filter times; corresponds to 2^(0–
9)×125us.
0x33
P24.06
Speed ratio
between encoder
mounting shaft
and motor
Users need to set this parameter when the encoder is not
installed on the motor shaft and the drive ratio is not 1.
Setting range: 0.001–65.535
1.000
P24.07
Control
parameters of
synchronous
motor
0x00000xFFFF
Bit0: Enable Z pulse calibration
Bit1: Enable encoder angle calibration
Bit2: Enable SVC speed measurement
Bit3: Reserved
Bit4: Reserved
0x0003

Table of Contents