0–65535
Set it to any non-zero value to enable password
protection.
00000: Clear previous user password and disable
password protection.
After user password becomes valid, if wrong password is
inputted, users will be denied entry. It is necessary to
keep the user password in mind.
Password protection will be effective one minute after
exiting function code edit state, and it will display
"0.0.0.0.0" if users press PRG/ESC key to enter function
code edit state again, users need to input the correct
password.
Note: Restoring to default values will clear user
password, use this function with caution.
Range: 0x00–0x27
Ones: Function selection of QUICK/JOG key
0: No function
1: Jogging
2: Reserved
3: Forward/reverse rotation switch-over
4: Clear UP/DOWN setting
5: Coast to stop
6: Switch over the running command reference mode in
sequence
7: Reserved
Tens: Reserved