Frequency Inverter ST600 Series High-Performance Multifunction VFD Function parameter list
-247-
zero speed
1: Disable
P91.07
Torque
compensation
selection
0x0000x111
Ones place: Frictional torque compensation
0: No
1: Yes
Tens place: Inertia compensation
0: No
1: Yes
Hundreds place: Compensation direction
0: In line with torque direction
1: Different from torque direction
0x000
P91.08
System
mechanical
parameters
identification
02
0: No operation
1: Enable system mechanical inertia identification
2: Enable mechanical friction torque identification
0
P91.09
Static friction
torque
compensation
coefficient
0.0100.0%
0.0%
P91.10
Sliding friction
torque
compensation
coefficient 1
0.0100.0%
0.0%
P91.11
Sliding friction
torque
compensation
coefficient 2
0.0100.0%
0.0%
P91.12
Sliding friction
torque
compensation
coefficient 3
0.0100.0%
0.0%
P91.13
High speed torque
compensation
coefficient
0.0100.0%
0.0%
P91.14
Compensation
frequency point of
static friction
torque
0.0%P91.15
1.0%
P91.15
Compensation
frequency point of
sliding friction
torque 1
P91.14–P91.16%
20.0%
P91.16
Compensation
frequency point of
sliding friction
P91.15–P91.17%
50.0%

Table of Contents