Frequency Inverter ST600 Series High-Performance Multifunction VFD Basic Operation Instructions
-75-
P03.15
Source of upper limit
frequency setup of
reverse rotation in
torque control
0: Keypad (P03.17)
111: the same as P03.14
0
P03.16
Keypad limit value of
upper limit frequency of
forward rotation in
torque control
0.00Hz–P00.03 (max. output frequency)
50.00 Hz
P03.17
Keypad limit value of
upper limit frequency of
reverse rotation in
torque control
0.00Hz–P00.03 (max. output frequency)
50.00 Hz
P03.18
Source of upper limit
setup of the torque
during motoring
0: Keypad (P03.20)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDIA
5: Modbus/Modbus TCP communication
6: PROFIBUS/CANopen/DeviceNet communication
7: Ethernet communication
8: Pulse frequency HDIB
9: EtherCAT/PROFITNET/Ethernet IP
communication
10: PLC
11: Reserved
Note: For these settings, 100% corresponds to the
motor rated current.
0
P03.19
Source of upper limit
setup of brake torque
0: Keypad (P03.21)
110: the same as P03.18
0
P03.20
Set upper limit of the
torque when motoring
via keypad
0.0300.0% (rated motor current)
180.0%
P03.21
Set upper limit of brake
torque via keypad
0.0300.0% (rated motor current)
180.0%
P17.09
Motor output torque
-250.0–250.0%
0.0%
P17.15
Torque reference value
-300.0–300.0% (rated motor current)
0.0%