Frequency Inverter ST600 Series High-Performance Multifunction VFD Basic Operation Instructions
-86-
P01.26
Deceleration time of
emergency-stop
0.0–60.0s
2.0s
P01.27
Time of starting section of
deceleration S curve
0.0–50.0s
0.1s
P01.28
Time of ending section of
deceleration S curve
0.0–50.0s
0.1s
P01.29
Short-circuit brake current
0.0–150.0% (of the rated VFD output current)
0.0%
P01.30
Hold time of short-circuit brake
at startup
0.00–50.00s
0.00s
P01.31
Hold time of short-circuit brake
at stop
0.00–50.00s
0.00s
P01.32
Pre-exciting time of jogging
0–10.000s
0.300s
P01.33
Starting frequency of braking
for jogging to stop
0–P00.03
0.00Hz
P01.34
Delay to enter sleep
0–3600.0s
0.0s
P05.01–
P05.06
Digital input function selection
1: Forward running
2: Reverse running
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
21: Acceleration/deceleration time selection 1
22: Acceleration/deceleration time selection 2
30: Acceleration/deceleration disabled
/
P08.06
Running frequency of jog
0.00Hz–P00.03 (max. output frequency)
5.00Hz
P08.07
Acceleration time at jogging
0.0–3600.0s
Model-
dependent
P08.08
Deceleration time at jogging
0.0–3600.0s
Model-
dependent
P08.00
Acceleration time 2
0.0–3600.0s
Model-
dependent
P08.01
Declaration time 2
0.0–3600.0s
Model-
dependent
P08.02
Acceleration time 3
0.0–3600.0s
Model-
dependent
P08.03
Declaration time 3
0.0–3600.0s
Model-
dependent