SC-CF-SBD Owners Manual34
Main Spa Side Control Single Pump System
Instructions
Up & Down Arrows
Automatic Water
Heater Start
Water Temperature
Display
Up & Down arrow keys are
used to set water temper-
ature.
Keeping pressure on the
keys will increase (or
decrease) the current
temperature setting.
The new and desired
temperature setting will
remain for 5 seconds on
the LED display as a
confirmation of its new value.
The Set Point light indicator (K-18) or triangular icon (K-19) tells the
user that the temperature shown is the desired and not the actual
temperature of the water.The temperature can be adjusted in 1
degree increments from 59 to 104°F (15 to 40°C.).
When the water temperature is 1°F lower than the set point, the
heater will be turned on until the water temperature reaches the set
point plus 1°F. The "Heater" indicator lights up when the heater is on.
The "Heater" indicator will flash if there is a request for more heat
but the heater has not started yet.
The 3-digit LED display shows the water temperature reading.
The reading will be refreshed every second.