EasyManua.ls Logo

SPX FLOW W63 - Operation of Valves; Air Connections for Actuators

SPX FLOW W63
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation Waukesha Cherry-Burrell Brand W60/W80 Valves
Page 14 95-03022 08/2018
Operation
Air Connections NOTE: Actual air pressure values may vary depending on the
valve size, actuator size, holding pressure requirements and
spring selection.
Maintainable Actuators
4", 5", and 6" Air-to-Raise
Air Pressure Range = minimum 50 psi to maximum 90 psi
(min. 3.4 bar to max. 6.2 bar)
1/8"-27 NPT Thread
4", 5", and 6" Air-to-Lower
Air Pressure Range = minimum 50 psi to maximum 90 psi
(min. 3.4 bar to max. 6.2 bar)
1/8"-27 NPT Thread
4" Air-to-Raise, 3-Position
Air Pressure Range = minimum 50 psi to maximum 90 psi
(3.4 bar to 6.2 bar)
1/8"-27 NPT Thread
A. Vent
B. Air In
Figure 3: 4", 5", and 6" Air-to-Raise
VA100-410a
A
B
A. Vent
B. Air In
Figure 4: 4", 5", and 6" Air-to-Lower
B
A
A. Vent
B. Full Air In
C. 3-Position Air
In
Figure 5: 4" Air-to-Raise, 3-Position
A
VA100-375a
B
C