Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
Page 28 95-03008-IEC 01/2019
Install the pump seal
NOTE: “D” seal shown. For “DG” seal, see “Type “DG” Seal” on
page 49 and for “E” seal, see “Type “E” Water-Cooled Balanced
Double Seal” on page 52. Type “F” Seal is a “D” seal with a water
cascade attachment.
1. Slide the seal drive collar
onto the stub shaft.
NOTE: Does no
t apply to the C-100; the C-100 does not require a
drive collar. Proceed to step 3.
2. Use the “A” and “B” dimensions in Table 3 to properly locate
the drive collar on the stub shaft. See Figure 40 and Figure
41. Tighten the setscrews to secure it in place.
3. Lubricate and install the seal O-ring into the seal.
NOTE: Do not lubricate the seals with any type of oil or
grease. The seal faces will be lubricated by the product being
pumped.
Figure 39 - Slide drive collar onto shaft
Figure 40 - Locate drive collar
Figure 41 -Drive Collar for “D” Seal
Type Adjustment
Table 3: Seal Chart
Model A B
C-114 9/16" (14,3 mm) 1 7/16" (36,5 mm)
C-216 9/16" (14,3 mm) 1 23/32" (43,6 mm)
C-218 9/16" (14,3 mm) 1 41/64" (41,6 mm)
C-328 9/16" (14,3 mm) 1 41/64" (41,6 mm)
Figure 42 - Lubricate and install O-ring