Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
01/2019 95-03008-IEC Page 45
Install the impeller onto the pump
1. Lightly stretch the stub shaft O-ring if needed.
2. Install the stub shaft O-ring onto the stub shaft.
3. Figure 106 shows the stub shaft O-ring and key installed.
Confirm that the stub shaft key is also installed in the keyway
gr
oove.
4. Install the impeller onto the stub shaft as shown.
NOTE: C-214 shown. C-218 and C-328 impellers have 4
blades.
Figure 104 - Lightly stretch O-ring
Figure 105 - Install stub shaft O-ring
Figure 106 - Stub shaft O-ring installed
Figure 107 - Install impeller on stub shaft