Maintenance Waukesha Cherry-Burrell
®
Brand C-Series Pump
Page 44 95-03008-IEC 01/2019
8. The arrow shows the stub shaft pin in the groove on the cup.
9. Install the backplate on the pump. Twist the backplate to lock
it on the retaining studs.
10. Figure 102 shows the seal with the backplate installed.
11. If supplied, install a water cascade (part no 60112+). Mount
the water cascade (Figure 103, item A) in the adapter above
the seal on the assembled backplate to flow water onto the
sea
l face.
The connection is 1/4 inch (6,35 mm) O.D. tubing.
The required flow is approximately 5 U.S. gallons per
hour (18
,9 liters per hour).
The recommended water supply is cool and filtered. If the
product solidifies at a cool temperature, use warm or hot
water.
NOTE: Seal Type "F" is a "D" seal with a water cascade
attachment.
Figure 100 - Stub shaft pin in groove
Figure 101 - Install backplate
Figure 102 - Seal with backplate installed
Figure 103 - Water cascade
attachment