32
The following table explains the meaning of each of the variables.
Exhaust T. [°C]
Read in degrees Celsius (°C) it tells you the exhaust temperature
monitored by the probe.
Water T. [°C] This is read in degrees Celsius (°C) and gives the water temperature.
Fan [rpm] Read in rpm, it tells you the rotation speed of the fan.
Auger [s]
Read in seconds and within 4 seconds the auger is active and feeding
pellet to the burner.
Service [h]
Read in hour’s shows the number of hours remaining to show faults
due to lack of maintenance. These must be reset by the technical
service during maintenance. The maintenance period must respect
the kilos of pellets burned.
Working hours [h]
Read in hours tells you the number of hours in Run Mode, Modulation
and Safety Mode.
Ignition [nr]
Read in number of occurrences informs how many ignitions have been
carried out since they were reset to zero.
Cod. Artic. Product Code.
Table 4 - Meaning of the variables
11. Alarm / Failure / Recommendation List – Tiemme Control
Anomalies
• Sond – Probe’s anomaly during the control in Check Up.
• Ignition Block – The message appears if the system has been is turned off during Ignition (after Preload) by an external
device: the system will stop only when it goes in Run Mode.
• Link Error – Lack of communication between the LCD or K control panels and the control board.
• Cleaning On – Periodic cleaning in progress.
• Flashing Hours - Wrong time and date in the event of prolonged power failure.
T
HE ANOMALIES DO NOT ORIGINATE THE SHUTDOWN OF THE EQUIPMENT
.
To switch off the device, in case of emergency, you must do the normal shutdown of the equipment. To do this, press the off button
for 3 seconds and allow it to deactivate until the word off appears on the display.
All alarms cause the machine to switch off with information about the error and activation of the alarm led. It will be necessary to
reset the alarm and restart. To reset the machine, press the “On/Off” button for 3 to 4 seconds until you hear a beep accompanied
by the message “Reset alarms in progress”.
If the resetting of alarms is successful, new information is displayed - Reset alarms Successful. In the Off state, if for any reason
the smoke temperature rises above 85ºC, the unit enters deactivation mode.