43
Figure 39 - Cleaning the burning basket
a)
b)
Figure 40 - Cleaning the interior of the unit
WARNING! The maintenance task frequency depends on the quality of the pellets.
Note: See the warning label and read the maintenance instructions in chapter 18.
15.3. Additional cleaning
K1200
Additional cleaning should be performed for every 1300-1700 lbs (600-800 kg) of pellets consumed.
To carry out this cleaning it is necessary to remove the side covers to gain access to the side covers of the combustion chamber,
remove the cover and with the hoover remove the ash. With the help of a steel brush 20-25 mm in diameter and 80 cm long clean
the fume passage area (Figure 41).
Figure 41 - Cleaning Vacuum the interior