59
The user interface was designed with a single button, a red/green LED and four yellow LEDs.
Figure 57 - User interface
When the pump is operating, the LED 1 is green. 4 yellow LEDs indicate the current performance of the pump, as shown in the
following table.
Active LED
Performance (%)
LED Green 0 (Standby)
LED Green + 1 LED Yellow 0 - 25
LED Green + 2 LED Yellow 25 - 50
LED Green + 3 LED Yellow 50 - 75
LED Green + 4 LED Yellow 75 - 100
Table 5 - Performance of the pump
Figure 58 - Performance of the pump
Note: the pump is configured as standard at full capacity (75-100%).
Changing the setting of the pump
Can be chosen between the view of the performance of pump and the view of settings, just press the button once.
If you need to change the pump performance, you must press the button for 2 seconds (Figure 59), after this action the LEDs
start blinking, then you must press the button until the desired setting (Table 6), after 10 seconds the display automatically
switches to the view of performance with alteration saved.
Figure 59 - Pump settings
Maximum manometric height (m) Settings
2-4
3-5
4-6
5-7
Table 6 - Pump settings
Alarms
If the pump detects one or more errors, the LED 1 changes from green to red when the alarm is activated the yellow LED indicates