PARTS REPLACEMENT
– 40 –
5. Fuses
For Ver. 1 and Ver. 1.5
(1) Remove
Upper case unit according to the procedure de-
scribed in item 1.
(2) Inspect
Fuse F1 [1]
Fuse F2 [2]
Fuse F3 [3] (For 120V only)
Defective Replace fuse as follows:
AC Voltage F1 (F3)
120V 5TT1A 5MT3.0
220V/240V 630mA
The Destination Countries F2
EC, WG, NBR, SC, SU EAK2.0
US, TW, HK, UK, AS, MAS, UE 5MT2.0
New fuse blown Inspect circuit
For Ver. 2
(1) Remove
Upper case unit according to the procedure de-
scribed in item 1.
(2) Inspect
Fuse F1 [1]
Fuse F2 [2]
Defective Replace fuse as follows:
AC Voltage F1
120V 5TT1A
220V/240V 630mA
The Destination Countries F2
EC, WG, NBR, SC, SU EAK3.15A
US, TW, HK, UK, AS, MAS, UE 5TT3A
New fuse blown Inspect circuit