EasyManua.ls Logo

Star Micronics NX-1020 - Fuses; Power Supply Unit

Star Micronics NX-1020
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PARTS REPLACEMENT
– 45 –
5. Power Supply Unit
(1) Remove
Upper case unit according to the procedure de-
scribed in item 1.
Connector [1]
Three tapping screws [2]
Two screws [3]
Two screws [4]
Power switch holder [5]
Power switch [6]
Power supply unit [7]
6. Fuses
(1) Remove
Power supply unit according to the procedure
described in item 5.
(2) Inspect
Fuse F1 [1]
Fuse F2 [2]
Fuse F3 [3]
Defective Replace fuse as follows:
AC Voltage F1
120V 5TT1A
220V/240V 630mA
Destination F2,F3
For US, UK, AS 5TT3A
For EC, WG, HK EAK3.15A
New fuse blown Inspect circuit