EasyManua.ls Logo

Star Micronics NX-1020 - Defective Motor Operation

Star Micronics NX-1020
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 67 –
TROUBLESHOOTING
4-3. Defective Motor Operation
NO
NO
START
LF-CMN
signal is normal?
*4
YES
LF-ø1,
ø2, ø3, ø4 are
normal? *5
YES
Replace
LF motor
Check operation
END
Check and relace
1) TR5
2) TR4
3) CPU
Check and replace
1) TA2
2) CPU
*4 See (8) waveform in item 10 of Chapter 7.
*5 See (9) waveform in item 10 of Chapter 7.
*6 See (6) waveform in item 10 of Chapter 7.
*7 See (7) waveform in item 10 of Chapter 7.
NO
NO
START
CR-CMN
signal is normal?
*6
YES
CR-ø1,
ø2, ø3, ø4 are
normal? *7
YES
Replace
CR motor
Check operation
END
Check and relace
1) TR6
2) TR1
3) CPU
Check and replace
1) TA1
2) CPU

Table of Contents