– 49 –
7-6. Control Codes Used for Peripheral Units
FUNCTION
Adjust drive pulse width for peripheral unit 1
CODE
<ESC> <BEL> n1 n2
(1B)
H (07)H n1 n2
DEFINITION RANGE
1 n1 127, 1 n2 127 (default setting n1 = n2 = 20)
OUTLINE
Adjusts drive pulse width for peripheral devices requiring
other than standard 200 ms pulse time and delay time
Energizing time = 10 × n1 (ms)
Delay time = 10 × n2 (ms)
Executed by <BEL>, <FS> codes.
NOTE
Adjustment is not necessary for standard cash drawers in the
U.S.A. market.
FUNCTION
Deferred drive command for peripheral unit 1
CODE
<BEL>
(07)
H
OUTLINE
Executes drive pulse for peripheral unit 1 (deferred).
FUNCTION
Immediate drive command for peripheral unit 1
CODE
<FS>
(1C)
H
OUTLINE
Executes drive pulse for peripheral unit 1 (immediate).
This code differs from the <BEL> code as follows:
When the printer receives an <FS> code, the command is
executed immediately. The <BEL> code is stored in the data
buffer in the same manner as other codes, and executed in the
order in which they are received.
ON
OFF
10 × n1 (ms) 10 × n2 (ms)
Printing and paper feed
are prohibited.