EasyManua.ls Logo

Status Pro T430 - Red (X+)-LED; Green (Y+)-LED

Default Icon
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20
Status Pro T430 User Guide
Red (X+)-LED
Red (X-)-LED
Green (Y+)-LED
Permanently lit
Laser is being moved in X+ direction
Calibration of X+ successful
5Hz-Flash
Calibration could not be conducted
Limiter for the X-axis has been triggered (the end of position or
the travel range has been reached or cannot be exited)
Short pulses Single steps in direction of X+
Permanently lit
Laser is being moved in X- direction
Calibration of X- successful
5Hz-Flash
Calibration could not be conducted
Limiter for X-axis has been triggered (the end of position or the
travel range has been reached or cannot be exited)
Short pulses Single steps in direction of X-
X+
X-
Permanently lit
Levelling: Y-axis is levelled
Calibration of Y-axis successful
2-Sensor-Control:
Y-axis completely arranged, target position reached
5Hz-Flash
Levelling: Y-axis is more than 1000 steps away from calibrated
levelling value
Levelling: Y-(Z-)axis displays restive values
Levelling not possible, outside measurement range
2-Sensor-Control:
Y-axis is more than 5 steps away from target position
Y+
SIGNALS AND SPECIAL FEATURES