Status Pro – T430 User Guide
Red (X+)-LED
Red (X-)-LED
Green (Y+)-LED
Permanently lit
Laser is being moved in X+ direction•
Calibration of X+ successful•
5Hz-Flash
Calibration could not be conducted•
Limiter for the X-axis has been triggered (the end of position or•
the travel range has been reached or cannot be exited)
Short pulses Single steps in direction of X+•
Permanently lit
Laser is being moved in X- direction•
Calibration of X- successful•
5Hz-Flash
Calibration could not be conducted•
Limiter for X-axis has been triggered (the end of position or the•
travel range has been reached or cannot be exited)
Short pulses Single steps in direction of X-•
X+
X-
Permanently lit
Levelling: Y-axis is levelled•
Calibration of Y-axis successful•
2-Sensor-Control:•
Y-axis completely arranged, target position reached
5Hz-Flash
Levelling: Y-axis is more than 1000 steps away from calibrated•
levelling value
Levelling: Y-(Z-)axis displays restive values•
Levelling not possible, outside measurement range•
2-Sensor-Control:•
Y-axis is more than 5 steps away from target position
Y+