Use the up or down button to select the X or GX or HX input point needed to modify. Press the
enter button the value start to flash, use the up or down button to set the value. press the enter
button to confirm, in which 1 represent normal close input, o represent normal open input. Please
note, the X and G and H of integrated unit are all shown as those in the above picture, due to the
confinement of the 7-segement code, Moreover, please pay attention to make clear distinguish
between X and H, since these two words have very similar display.
Login authorization is required for the input type modification. Once modify parameter and press
the enter button in non login stat, login menu will pop up
14 parking floor allowed
Parking floor allowed
Actual floor
Use up and down button to select the floor need to modify. Please note, the floor mentioned here is
the actual floor ( or the control floor) press the enter button. The selected value start to flash, press
the up and down button to set the value. press the enter button to confirm, in which 1 mean
parking allowed, 0 mean parking prohibited.
Login authorization is required for the parking floor allowed modification, Once modify
parameter and press the enter button in non login stat, login menu will pop up.
15 instruction registration
Use up and down button to select the floor needed to register the instruction, press the enter button,
to register the instruction.
16 self-study instruction
The above picture will display once enter the menu.