Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
80
Self-study instruction
Press the enter button when need to do the hoist way study, the figure in the lowest order start to
flash, press the up button , figure 0 change to 1. Press the enter button again to confirm, as the
above fig. the elevator start to do the hoist way self-study. If the value is set to 2, asynchronous
motor parameter self-study will start.
Login authorization is required for the self-study instruction modification, Once modify parameter
and press the enter button in non login stat, login menu will pop up.
17 the front door opening allowed
Door open allowed enable or not
Floor
Front door
The above picture mean: shield 1 floor front door open allowed. Fd is the abbreviation of Front
door. Press the up and down button to browse the front door open allowed parameter of
corresponding floor. Press the enter button to make modification. The figure in the lowest order
starts to flash, use up or down button to modify the figure into 0 or 1. Press the enter button to
confirm the modification (0 is to shield front door open allowed function, 1 is to allow front door
open function)
Login authorization is required for the front door open allowed modification, Once modify
parameter and press the enter button in non login stat, login menu will pop up.
18 rear door open allowed
Door open allowed or not
Floor
Rear door
The above picture mean: shield 1 floor rear door open allowed. Rd is the abbreviation of rear door.
Press the up and down button to browse the rear door open allowed parameter of corresponding
floor. Press the enter button to make modification. The figure in the lowest order starts to flash,
use up or down button to modify the figure into 0 or 1. Press the enter button to confirm the
modification (0 is to shield rear door open allowed function, 1 is to allow rear door open function)
Login authorization is required for the rear door open allowed modification, Once modify
parameter and press the enter button in non login stat, login menu will pop up.
19 control parameter reset