8
EN
a) Hard starting
b) Inconsistent
working
c) Loss of power
whilst operating
No fuel
Stale fuel or build-ups in tank
Incorrect starting procedure
Spark plug disconnected
The spark plug is wet or the spark plug
electrodes are dirty or placed inadequately
Air lter clogged
Incorrect oil for the season
Fuel evaporation in the carburetor
(vapor lock) due to high temperatures
Fault in carburation
Hard starting
Dirty electrodes or incorrect gap
The spark plug cap is inserted incorrectly
Air lter clogged
Throttle trigger in «CHOKE» position
Fault in carburation
Fault in ignition
Air lter clogged
Fault in carburation
Governor out of phase with respect
to the accelerator
Check and top up (see 5.1.3)
Empty fuel tank and rell with fresh fuel
Perform the starting procedure
correctly (see 5.2)
Check that the spark plug cap ts well
over the plug terminals (see 5.1.4)
Check (see 6.6)
Check and clean (see 6.5)
Replace with proper oil (see 6.3)
Wait for a few minutes then start again
(see 5.3)
Contact a Licensed Service Centre
Contact a Licensed Service Centre
Check (see 6.6)
Check that the cap is tted correctly
(see 5.1.4)
Check and clean (see 6.5)
Move the lever to the «FAST» position
Contact a Licensed Service Centre
Contact a Licensed Service Centre
Check and clean (see 6.5)
Contact a Licensed Service Centre
Adjust the cable (see 6.7)
PROBLEM LIKELY CAUSE SOLUTION